Type: Super slim cassette
Technology: inverter air conditioner
Energy Class: А++/A+++
Cooling SEER: 6.30
Heating SCOP: 5.10
The new Midea MCD-18HRFN1-QRD0 cassette type inverter air conditioner features a 360 degree air flow panel with independent vane control to ensure that air is distributed to every corner of the room.
The air conditioner is designed with a very low profile which makes it perfect for use in shallow ceiling voids where standard cassettes would be too deep.
The removable lifting panel of the indoor unit can be lifted down for max 4 meters, making the clean process much easier.
360° Air Flow Panel – with the 360° air flow panel, the air can be distributed to every corner of the room.
Wired Controller – compared with infrared remote controller, wired controller can be fixed on the wall and avoid mislaying. It’s mainly used for commercial zone and makes air conditioner control more convenient.
ON-OFF Switch – with the reserved ports, a remote ON-OFF switch can be easily connected to control the air conditioner.
Alarm Port – the built-in PCB can output alarm signal, which makes setting up an external alarm light or vibration gauge possible
Built-in Drain Pump – the drain pump can lift the condensing water up to 750mm upmost.
Low Ambient Cooling – with built-in low ambient kit or special designed PCB, outdoor fan speed can be changed automatically according to condensation temperature. The air conditioner can run cooling operation even when the outdoor ambient temperature down to -15℃.
Twin Combination – the units can be installed as twin systems: one outdoor unit can be connected with two same indoor units. The indoor units can be combined in any of the different available ratings.
Self-diagnosis and Auto-protection – once abnormal operation or parts failure happen, the unit will shut off automatically to protect the system. Meanwhile it will indicate protection or error code for fast service.
Anti-cold Air Function – indoor fan speed is regulated automatically from the lowest grade to the setting grade according to evaporator temperature when the unit just starts heating operation. This function can prevent cold air blowing out to avoid discomfort to the users.
Auto Restart Function – if the air conditioner breaks off unexpectedly due to the power cut, it will restart with the previous setting mode automatically when the power resume.
Turbo Mode – by pressing the turbo button on the remote controller, the unit will enter turbo mode with ultra-high speed and reach the set temperature more quickly. After running 20 minutes in turbo mode, the indoor fan will automatically recover the preset speed.
Refrigerant Leakage Detect – Indoor unit will show error code “EC” and stop automatically when refrigerant leakage is detected. This function can better protect compressor being damaged by high temperature due to refrigerant leakage.
*Note: The image is for reference purposes only. The actual product could differ from the image shown.
Terms & Conditions:
Model |
Indoor Unit | MCD-24HRFN1-QRD0 | |
Outdoor Unit | MOCA30U-24HFN1-QRD0 | ||
Power Supply |
V/O/Hz | 220-240 / 1 / 50 | |
Capacity |
Cooling | kW | 7.03 (1.20 – 8.21) |
Heating | 7.03 (1.20 – 8.65) | ||
Power Input |
Cooling/ Heating | kW | 0.400 – 3.155 / 0.400 – 3.090 |
Design |
Cooling | kW | 7 |
Heating (-7°C) | 5.8 | ||
Heating (2°C) | 5.6 | ||
SEER |
Cooling | W/W | 6.1 |
SCOP (-7°C) |
Heating | 4 | |
SCOP (2°C) |
Heating | 5.1 | |
Energy Efficiency Class |
Cooling | A++ | |
Heating (-7°C) | A+ | ||
Heating (2°C) | A+++ | ||
Running Current |
Cooling/ Heating | A | 1.8 – 14.4 / 1.8 – 14.1 |
Air Flow (indoor unit) |
m3/h | 1450 / 1250 / 1100 | |
Sound Pressure (indoor unit) |
dB(A) | 46 / 42 / 39 | |
Sound Power (indoor unit) |
dB(A) | 61 | |
Air Flow (outdoor unit) |
m3/h | 2700 | |
Sound Pressure (outdoor unit) |
dB(A) | 60.5 | |
Sound Power (outdoor unit) |
dB(A) | 65 | |
Dimensions W x D x H |
Indoor Unit | mm | 840x840x205 |
Weight |
kg | 24 | |
|
Outdoor Unit | mm | 845x363x702 |
|
kg | 49 | |
Refrigerant piping (liquid / gas) |
mm | 9.52 / 15.9 | |
Max. refrigerant pipe length |
m | 50 | |
Max. difference in level |
25 | ||
Operation Temperature |
Cooling | °C | -15 ~ 50 |
Heating | -15 ~ 24 | ||
Refrigerant |
R410A |